M2A, Hydrogen (H2) specific LEL 0-100% sensor (catalytic) / transmitter with j-box, CSA version
  • Operates with or without a controller
  • Direct digital readout with OLED cold temperature display
  • Infrared sensor for combustibles and CO2
  • 4 to 20 mA and digital Modbus outputs standard
  • Two fully programmable alarm relays and fail relay
  • Non-intrusive calibration via magnetic wand
  • Patented water repellent sensor coating
  • User friendly setup, push buttons and OLED menus
  • Long life sensors (2 + years typical)
  • Short Description - M2A, HYDROGEN(H2) SPECIFIC LEL 0-100% SENSOR
  • Item Name - Stand Alone Sensor/Transmitter
  • Type - Catalytic, Explosion Proof
  • Series - M2A
  • Material - Cast Aluminum
  • Includes - Junction Box
  • Suitable For Use With - M2A Stand Alone Transmitter
  • Resolution - 1% LEL
  • Temperature Rating - -40 to 75
  • Dimensions - 8-1/2 in H x 5.2 in W x 4-1/2 in D
  • Detects - Hydrogen
  • Sensor Range - 0 to 100% LEL
  • Finish - Epoxy Powder Coated
  • Marketing Description - The RKI M2Aâ„¢ is a state of the art transmitter that can operate as an independent, stand alone monitor or as part of an integrated system. The M2A connects with an analog or digital signal to virtually any controller, PLC or DCS. Setup procedures are simplified with user friendly push buttons and OLED menus. It utilizes a magnetic wand technique for performing non-intrusive calibration. The M2A provides an automatic zero drift correction feature, which results in more stable readings and reduces the need for adjustments due to sensor aging. The housing of the M2A does not need to be opened for zeroing or calibration, making it unnecessary to declassify the area for routine maintenance. It is designed so that a complete field calibration can be performed by one person. Sensor construction is rated class I, division 1 groups B, C, D for flammables, CO, H2S, O2 and CO2 and class I, division 2 for all other toxics. The transmitter provides a 4 to 20 mA output in addition to a Modbus digital output. It also has two levels of alarms with relays, plus a fail alarm with relay. A digital display of the gas concentration, as well as alarm and status lights, can be viewed through the front window. The toxic sensors are electrochemical-type plug-in sensors, which provide high-specificity, fast response and long life. The plug-in design allows quick replacement in the field with no tools required. Toxic sensors are designed for use in class I, division 2 hazardous locations. Sensors available for NH3, SO2, PH3, AsH3 and HCN. The M2A represents the latest leading edge technology in sensor/transmitters today.