Applications: Hazardous material, Mining, Refineries/petrochemical, Water/wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire services
Key Features:
- Operates 3,000 hours on alkaline batteries (GP-03 operates 35 or 30 hrs on alkaline/Ni-MH)
- Pocket size 2.1 in. (W) x 2.6 in. (H) x 0.9 in. (D)
- Lightweight (2.8 oz.)
- Impact, dust, and water resistant (IP-67)
- Replaceable rubber boot
- Datalog from 5 to 300 hours with adjustable intervals
- Audible / visual / vibration alarms
- Automatic backlight
- Low battery alarm
- Hydrogen sulfide (H2S)
- Detection principle: Electrochemical
- Detection range: 0-100 ppm
- Alarm set points: 1st - 10 ppm 2nd - 30 ppm TWA - 1 ppm STEL - 5 ppm Over - 100 ppm
- Alarm types: Gas alarms: 1st and 2nd (user adjustable), OVER alarm, STEL and TWA Trouble alarms: Sensor connection, low battery circuit failure, and calibration range error
- Gas sampling: Diffusion
- Response time: T90 in 30 seconds
- Accuracy: 5 percent of reading or å± 5 ppm H2S
- Data logging: 10 second intervals = 5 hours, 5 minute intervals = 150 hours, 10 minute intervals = 300 hours Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings
- Continuous operation: Alkaline dry cell: more than 3,000 hours (at 25å¡C, no backlight)
- Safety rating: ATEX/IECEx approved. CSA classified, ?ÛÏC/US?Û, as intrinsically safe, Class I, Division 1, Groups A, B, C, D (pending)
- Enclosure: Dust and water resistant with IP-67 rating
- Display: Digital LCD, gas name & concentration, auto backlighting during alarm, operation icon, battery icon
- 3-year warranty
- Rubber protective boot
- Alkaline batteries
- Alligator clip
- Wrist strap
- Datalog software