Applications: Hazardous material, Mining Refineries / petrochemical, Water / wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire services
Key Features:
- Personal monitoring for HCN
- Operates 3,000 hours on alkaline
- Pocket size 2.1"(W) x 2.6"(H) x 0.9"(D)
- Light weight 2.8 ounces
- Impact, dust, and water resistant (IP-67)
- Replaceable rubber boot
- Data log 10 to 600 hours with adjustable intervals
- Audible / visual / vibration alarms
- Automatic backlight
- Low battery alarm
- Intrinsically safe, ATEX and C / US approvals
- 3 year warranty
- Gas Detected: Hydrogen Cyanide
- Detection principle: Electrochemical
- Detection range: 0 ~ 30.0 ppm (0.1 ppm)
- Alarm set points: 1st: 5.0 ppm, 2nd: 10.0 ppm, 3rd: 30.0 ppm, TWA: 4.7 ppm, STEL: 10 ppm
- Alarm types: Gas alarms: 1st, 2nd and 3rd (user adjustable), OVER alarm, STEL and TWA, Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error
- Gas sampling: Diffusion
- Response time: T90 in 30 seconds
- Accuracy: ± 10% of reading or ± 5 % of full scale
- Data logging: 10 second intervals = 5 hours, 5 minute intervals = 150 hours, 10 minute intervals = 300 hours Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings.
- Continuous operation: Alkaline dry cell: 3,000 hours (at 25°C, no backlight)
- Safety rating: ATEX/IECEx approved. QPS classified, “C / US”, as intrinsically safe, Class I, Division 1, Groups A, B, C, D
- Enclosure: Dust and water resistant with IP-67 rating
- Display: Digital LCD, gas name & concentration, auto backlighting during alarm, operation icon, battery icon
- Rubber protective boot
- Alkaline batteries
- Alligator clip
- Wrist strap
- Datalog software