RKI Explosion Proof Sensor/Transmitter, Stand Alone, Series: M2A, Detects: Combustible Gas, 0 to 100% LEL Sensor, 1% LEL Resolution, -40 to 75 deg C, Cast Aluminum, Epoxy Powder Coated, 8-1/2 in H x 5.2 in W x 4-1/2 in D, Includes: Junction Box, Remote Detector, Calibration Adapter/Splash Guard, For Use With: Gas Monitors
- Operates with or without a controller
- Direct digital readout with OLED cold temperature display
- 4 to 20 mA and digital Modbus outputs standard
- 2 fully programmable alarm relays and fail relay
- Non-intrusive calibration via magnetic wand
- Explosion proof construction
- Patented water repellent sensor cover
- User friendly setup, push buttons and OLED menus
- Long life sensors (2+ years typical)
- Short Description - M2A sensor/Xmitter w/j-box,%LEL,w/remote det & cal adapter/splash guard,Specify Cal_____
- Warranty - 1 Year
- Item Name - Explosion Proof Sensor/Transmitter
- Type - Stand Alone
- Series - M2A
- Material - Cast Aluminum
- Includes - Junction Box, Remote Detector, Calibration Adapter/Splash Guard
- Suitable For Use With - Gas Monitors
- Resolution - 1% LEL
- Temperature Rating - -40 to 75
- Dimensions - 8-1/2 in H x 5.2 in W x 4-1/2 in D
- Detects - Combustible Gas
- Sensor Range - 0 to 100% LEL
- Finish - Epoxy Powder Coated
- Marketing Description - The RKI M2Aâ„¢ is a state-of-the-art transmitter that can operate as an independent, stand alone monitor or as part of an integrated system. The M2Aâ„¢ connects with an analog or digital signal to virtually any controller, PLC, or DCS. Setup procedures are simplified with user friendly push buttons and OLED menus. It utilizes a magnetic wand technique for performing non-intrusive calibration. The M2Aâ„¢ provides an automatic zero drift correction feature, which results in more stable readings and reduces the need for adjustments due to sensor aging. The housing of the M2Aâ„¢ does not need to be opened for zeroing or calibration, making it unnecessary to declassify the area for routine maintenance. It is designed so that a complete field calibration can be performed by one person. Sensor construction is rated Class I, Div. 1 Groups B, C, D for flammables, CO, H2S, O2, and CO2, and Class I, Div. 2 for all other toxics. The transmitter provides a 4 to 20 mA output in addition to a Modbus digital output. It also has two levels of alarms with relays, plus a fail alarm with relay. A digital display of the gas concentration, as well as alarm and status lights, can be viewed through the front window. The toxic sensors are electrochemical type plug-in sensors, which provide high specificity, fast response, and long life. The plug-in design allows quick replacement in the field with no tools required. Toxic sensors are designed for use in Class I, Div. 2 hazardous locations. Sensors available for NH3, SO2, PH3, AsH3, and HCN. The M2Aâ„¢ represents the latest leading edge technology in sensor/transmitters today.
RKI_652640RK_Specification_Sheet.pdf
RKI_652640RK_Manual.pdf